{"id":6816,"date":"2021-10-08T16:29:13","date_gmt":"2021-10-08T20:29:13","guid":{"rendered":"https:\/\/certek.com\/kb4\/?p=6816"},"modified":"2023-09-12T08:38:28","modified_gmt":"2023-09-12T12:38:28","slug":"using-trancloud-for-payment-processing-in-artisan","status":"publish","type":"ht_kb","link":"https:\/\/certek.com\/kb4\/knowledge-base\/using-trancloud-for-payment-processing-in-artisan\/","title":{"rendered":"Using TranCloud for Payment Processing in Artisan"},"content":{"rendered":"\n<p>Artisan supports TranCloud, a device from the software company<strong><a href=\"https:\/\/datacapsystems.com\/\"> Datacap<\/a><\/strong>. The <strong><a href=\"https:\/\/datacapsystems.com\/supported-features-processors\">TranCloud<\/a><\/strong> is a 2 by 2 inch device that works via cloud technology, connecting to PIN pads and payment processors.\u00a0<\/p>\n<h3><strong>Installation<\/strong><\/h3>\n<p>To use the TranCloud device, connect the device to a battery backup on the <strong>battery side<\/strong>, not the surge side. Next, connect an ethernet cable from the ethernet port on the TranCloud to your Internet router or network switch. <strong>Note:\u00a0<\/strong>Don&#8217;t plug the TranCloud into a wireless router unless the PIN pads are also connected to that wireless router. They must be on the same subnet.<\/p>\n<p>If you&#8217;re using a wired network, you can place the TranCloud anywhere you like. However, it&#8217;s recommended that you place the TranCloud near your main register so you remember where the device is located.<\/p>\n<p>Connect the PIN pad into the battery backup. This is recommended in case of a power outage.<\/p>\n<p><img decoding=\"async\" class=\"aligncenter\" src=\"https:\/\/certek.com\/kb4\/wp-content\/uploads\/2020\/08\/2020-08-28_17h29_29.png\" \/><\/p>\n<h3><strong>Setting Up In Artisan<\/strong><\/h3>\n<p>Head to &#8220;<strong>Go<\/strong>&#8221; and &#8220;<strong>Device Configuration<\/strong>.&#8221;<\/p>\n<p><a href=\"https:\/\/certek.com\/kb4\/wp-content\/uploads\/2021\/10\/2021-10-08_12h21_12.png\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-6818\" src=\"https:\/\/certek.com\/kb4\/wp-content\/uploads\/2021\/10\/2021-10-08_12h21_12.png\" alt=\"\" width=\"1039\" height=\"756\" srcset=\"https:\/\/certek.com\/kb4\/wp-content\/uploads\/2021\/10\/2021-10-08_12h21_12.png 1039w, https:\/\/certek.com\/kb4\/wp-content\/uploads\/2021\/10\/2021-10-08_12h21_12-300x218.png 300w, https:\/\/certek.com\/kb4\/wp-content\/uploads\/2021\/10\/2021-10-08_12h21_12-1024x745.png 1024w, https:\/\/certek.com\/kb4\/wp-content\/uploads\/2021\/10\/2021-10-08_12h21_12-768x559.png 768w\" sizes=\"auto, (max-width: 1039px) 100vw, 1039px\" \/><\/a><\/p>\n<p>Click on &#8220;<strong>Business and Financial Settings<\/strong>,&#8221; then &#8220;<strong>Payment Processing Settings<\/strong>.&#8221;<\/p>\n<p><a href=\"https:\/\/certek.com\/kb4\/wp-content\/uploads\/2021\/10\/2021-10-08_12h22_30.png\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-6819\" src=\"https:\/\/certek.com\/kb4\/wp-content\/uploads\/2021\/10\/2021-10-08_12h22_30.png\" alt=\"\" width=\"1038\" height=\"752\" srcset=\"https:\/\/certek.com\/kb4\/wp-content\/uploads\/2021\/10\/2021-10-08_12h22_30.png 1038w, https:\/\/certek.com\/kb4\/wp-content\/uploads\/2021\/10\/2021-10-08_12h22_30-300x217.png 300w, https:\/\/certek.com\/kb4\/wp-content\/uploads\/2021\/10\/2021-10-08_12h22_30-1024x742.png 1024w, https:\/\/certek.com\/kb4\/wp-content\/uploads\/2021\/10\/2021-10-08_12h22_30-768x556.png 768w\" sizes=\"auto, (max-width: 1038px) 100vw, 1038px\" \/><\/a><\/p>\n<p><a href=\"https:\/\/certek.com\/kb4\/wp-content\/uploads\/2021\/10\/2021-10-08_12h24_03.png\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-6821\" src=\"https:\/\/certek.com\/kb4\/wp-content\/uploads\/2021\/10\/2021-10-08_12h24_03.png\" alt=\"\" width=\"1041\" height=\"759\" srcset=\"https:\/\/certek.com\/kb4\/wp-content\/uploads\/2021\/10\/2021-10-08_12h24_03.png 1041w, https:\/\/certek.com\/kb4\/wp-content\/uploads\/2021\/10\/2021-10-08_12h24_03-300x219.png 300w, https:\/\/certek.com\/kb4\/wp-content\/uploads\/2021\/10\/2021-10-08_12h24_03-1024x747.png 1024w, https:\/\/certek.com\/kb4\/wp-content\/uploads\/2021\/10\/2021-10-08_12h24_03-768x560.png 768w\" sizes=\"auto, (max-width: 1041px) 100vw, 1041px\" \/><\/a><\/p>\n<p>Each station that handles payment processing should have its own payment processing profile. This is especially important if you&#8217;re using more than one PIN pad. (If you&#8217;re using just one PIN pad, select &#8220;<strong>Integrated Processing<\/strong>&#8221; from the dropdown).<\/p>\n<p><img decoding=\"async\" class=\"aligncenter\" src=\"https:\/\/certek.com\/kb4\/wp-content\/uploads\/2020\/08\/2020-08-28_17h47_06-1.png\" \/><\/p>\n<p>If you&#8217;re using more than one PIN pad, select &#8220;<strong>Edit List<\/strong>&#8221; from the &#8220;<strong>Select the Payment Processing Profile&#8230;<\/strong>&#8221; dropdown.<\/p>\n<p>Select &#8220;<strong>Add<\/strong>&#8221; and input a &#8220;<strong>Payment Profile Name<\/strong>.&#8221; This should correlate with your station number. If you&#8217;re setting up a payment profile for station number 1, we recommend calling the profile &#8220;<strong>001-01<\/strong>.&#8221;<\/p>\n<p><img decoding=\"async\" class=\"aligncenter\" src=\"https:\/\/certek.com\/kb4\/wp-content\/uploads\/2020\/08\/2020-08-28_17h51_48.png\" \/><\/p>\n<p>Hit &#8220;<strong>OK<\/strong>&#8221; when finished.<\/p>\n<p>In the &#8220;<strong>Payment Processing Method<\/strong>&#8221; section, select &#8220;<strong>TranCloud Payment Appliance from DataCap<\/strong>&#8221; from the dropdown.<\/p>\n<p><img decoding=\"async\" class=\"aligncenter\" src=\"https:\/\/certek.com\/kb4\/wp-content\/uploads\/2020\/08\/2020-08-28_17h54_38.png\" \/><\/p>\n<p><strong>Merchant ID\/Host ID, Terminal ID, TranCloud ID, and MAC Address<\/strong><\/p>\n<p>This information is for the PIN pad. It is located on your setup\/VAR sheet sent to you from your payment processor, or CerTek.\u00a0<\/p>\n<p>The MAC address might also be found on the PIN pad&#8217;s box or the back of your PIN pad.\u00a0<strong>Note:\u00a0<\/strong>The Lane 5000 no longer prints the MAC address for security reasons. On your PIN pad, press 0 &#8211; 0 &#8211; 0 &#8211; 1, select Option 2, Option 1, and scroll up on the screen to see the MAC address.\u00a0<\/p>\n<p><img decoding=\"async\" class=\"aligncenter\" src=\"https:\/\/certek.com\/kb4\/wp-content\/uploads\/2020\/08\/2020-08-28_17h39_00.png\" \/><\/p>\n<p><strong>Proxy Server IP Address<\/strong><\/p>\n<p>This field is rarely used.<\/p>\n<p><strong>Terminal Device<\/strong><\/p>\n<p>This corresponds with the brand of your PIN pad.<\/p>\n<p><strong>Processing Company<\/strong><\/p>\n<p>Select which processing company corresponds with your PIN pad.<\/p>\n<p><strong>Processing Timeout<\/strong><\/p>\n<p>Make sure this is set to 90 seconds.<\/p>\n<h3><strong>Next Steps<\/strong><\/h3>\n<p>When you&#8217;re finished, press &#8220;<strong>Initialize&#8221; <\/strong>and closely watch your PIN pad screen to see if a &#8220;<strong>Loading&#8230;<\/strong>&#8221; message displays. This should only last for a few seconds before displaying &#8220;<strong>Welcome<\/strong>.&#8221; The PIN pad will reboot, which should take about two minutes.<\/p>\n<p>Once the PIN pad has finished rebooting, try testing some cards. Begin with a VISA card with a chip, then work your way up to MasterCard, AMEX, Discover, ApplePay, and MasterCard tap.\u00a0<\/p>\n<p><strong>Note: <\/strong>TranCloud does not currently capture signatures due to compliance with VISA, MasterCard, AMEX, and Discover.\u00a0<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Artisan supports TranCloud, a device from the software company Datacap. The TranCloud is a 2 by 2 inch device that works via cloud technology, connecting to PIN pads and payment processors.\u00a0 Installation To use the TranCloud device, connect the device to a battery backup on the battery side, not the&#8230;<\/p>\n","protected":false},"author":17,"comment_status":"closed","ping_status":"closed","template":"","format":"standard","meta":{"_eb_attr":"","_monsterinsights_skip_tracking":false,"footnotes":"","_members_access_role":[],"_members_access_error":""},"ht-kb-category":[403],"ht-kb-tag":[],"class_list":["post-6816","ht_kb","type-ht_kb","status-publish","format-standard","hentry","ht_kb_category-datacap"],"_links":{"self":[{"href":"https:\/\/certek.com\/kb4\/wp-json\/wp\/v2\/ht-kb\/6816","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/certek.com\/kb4\/wp-json\/wp\/v2\/ht-kb"}],"about":[{"href":"https:\/\/certek.com\/kb4\/wp-json\/wp\/v2\/types\/ht_kb"}],"author":[{"embeddable":true,"href":"https:\/\/certek.com\/kb4\/wp-json\/wp\/v2\/users\/17"}],"replies":[{"embeddable":true,"href":"https:\/\/certek.com\/kb4\/wp-json\/wp\/v2\/comments?post=6816"}],"version-history":[{"count":8,"href":"https:\/\/certek.com\/kb4\/wp-json\/wp\/v2\/ht-kb\/6816\/revisions"}],"predecessor-version":[{"id":7426,"href":"https:\/\/certek.com\/kb4\/wp-json\/wp\/v2\/ht-kb\/6816\/revisions\/7426"}],"wp:attachment":[{"href":"https:\/\/certek.com\/kb4\/wp-json\/wp\/v2\/media?parent=6816"}],"wp:term":[{"taxonomy":"ht_kb_category","embeddable":true,"href":"https:\/\/certek.com\/kb4\/wp-json\/wp\/v2\/ht-kb-category?post=6816"},{"taxonomy":"ht_kb_tag","embeddable":true,"href":"https:\/\/certek.com\/kb4\/wp-json\/wp\/v2\/ht-kb-tag?post=6816"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}